u It adopts imported components from Europe. American and Japan with low failure rate and long service life.
u It is simple in structure, easy to operate. The efficiency of production can be greatly improved.
u It adopts PID controlling method with high precision and realizes the thermo regulate precision of ±1%.
u It is convenient to be moved and convenient to be installed and maintained.
Gloss of forming products can be improved and its quality is stable.
Main Technical Parameters:
WDK –A direct cooling
|
Model
|
MSK-1A
|
MSK-2A
|
MSK-3A
|
MSK-4A
|
|
Temperature controlling range
|
Normal temperature -120℃
|
|
Temperature controlling method
|
Japan RKC PID Adjustment
|
|
Power supply (v)
|
AC 380V 50Hz
|
|
Heat transfer medium
|
Water
|
|
Cooling method
|
Direct cooling
|
|
Heating power(kw)
|
3
|
9
|
20
|
32
|
|
Pump flow
|
58
|
66
|
120
|
200
|
|
Motor power
|
0.55
|
1.1
|
1.5
|
2.2
|
|
Pump pressure
|
2
|
2.5
|
3
|
4
|
|
Cooling water tubing
|
1/2
|
1/2
|
1/2
|
11/2
|
|
Circulatory water tubing
|
1/2
|
3/4
|
1
|
1
|
|
Outside dimension(LxWxH)(cm)
|
64x31x64
|
64x31x74
|
80x40x80
|
80x40x90
|
|
Weight(kg)
|
45
|
70
|
100
|
110
|
Main technical parameters:
WDR indirect cooling
|
Model
|
MSR-1
|
MSR-3
|
MSR-5
|
MSR-6
|
|
Temperature controlling range
|
45℃~160℃(45℃~250℃)
|
|
Temperature controlling method
|
Japan RKC PID Adjustment
|
|
Power supply (v)
|
AC 380V 50Hz
|
|
Heat transfer medium
|
Oil
|
|
Cooling method
|
Indirect cooling
|
|
Motor power(kw)
|
0.75
|
0.75
|
1.5
|
2
|
|
Heating power
|
3
|
9
|
20
|
32
|
|
Pump flow
|
30
|
60
|
140
|
200
|
|
Pump pressure
|
2
|
2.5
|
3
|
4
|
|
Cooling water tubing
|
1/2
|
1/2
|
1/2
|
1/2
|
|
Circulatory water tubing
|
1/2
|
3/4
|
1
|
11/2
|
|
Outside dimension(LxWxH)(cm)
|
70x31x64
|
77x35x70
|
110x60x130
|
130x60x130
|
|
Weight(kg)
|
45
|
70
|
110
|
120
|
Remark: If the equipment or the technological parameters have some change, we shall not make a notice separatel
|